Thickener operation: bed level, flocculant dosing, rise rate and troubleshooting

Thickener operation: rise rate and solids loading, flocculant dose and pump flow, bed level and bed pressure control, and a troubleshooting guide.

· 5 minute read · By

A thickener is a large circular tank in which solids settle out of a slurry. Clarified water overflows the rim, and thickened slurry is pumped from the cone at the base. Flocculant, a long-chain polymer, is added to the feed to bind fine particles into larger aggregates (flocs) that settle much faster.

The settled solids form a bed in the lower part of the tank, and slowly rotating rakes move the bed towards the central outlet. The operating objective is to hold the bed at the correct depth. A shallow bed produces a thin, watery underflow; a deep bed allows solids to escape to the overflow or overloads the rakes.

This article covers the operating parameters, flocculant dosing, bed control and troubleshooting. Sizing a new thickener from settling tests is covered in thickener sizing, and the thickener's role in the site water balance in plant water balance.

Zones in an operating thickenerFeed enters a central feedwell where flocculant is mixed in. Clear liquor rises to the overflow launder. Below the clear zone, flocculated solids settle as a hindered settling zone onto a compacting bed, which the rakes move to the underflow cone.feedwellclear liquorclear liquorhindered settlinghindered settlingbed (compaction)bed (compaction)rakesfeed + flocculantoverflowunderflow to pumpbed level
A thickener in operation. Operators control the bed: its level or mass, the underflow density it produces, and the clarity of the liquor above it.

Rise rate and solids loading

rise rate=QoverflowAsolids loading=MsA

where

Qoverflow
overflow volume flow (m³/h)
A
thickener area (m²)
Ms
dry solids feed rate (t/h); solids loading in t/h per m²

Worked example: a 30 m diameter thickener has an area of 707 m². It receives 300 t/h of solids and overflows 280 m³/h. The rise rate is 280 ÷ 707 = 0.40 m/h and the solids loading 300 ÷ 707 = 0.42 t/h per m². Expressed as a unit area, this is 707 ÷ (300 × 24) = 0.098 m² per t/d. If settling tests gave a design unit area of 0.14 m² per t/d for the target underflow density, the thickener is operating well beyond its design loading and will have difficulty reaching that density without additional flocculant, a deeper bed or a lower feed rate.

Flocculant dosing

Qfloc=D×Msc

where

Qfloc
flocculant solution flow (L/h)
D
flocculant dose (g/t of dry solids)
c
flocculant solution strength (g/L); 0.25% w/v is 2.5 g/L

Worked example: a dose of 25 g/t on 300 t/h of solids is 7.5 kg/h of flocculant. As a 0.25% stock solution (2.5 g/L), the dosing pump delivers 7,500 ÷ 2.5 = 3,000 L/h. In-line dilution to 0.025% before the feedwell gives 30,000 L/h, which distributes the flocculant through the feed more evenly. The reagent dosing calculator converts g/t to pump flow.

Powder flocculant must be wetted and aged before use in accordance with the supplier's instructions. Undissolved polymer lumps ("fish eyes") waste flocculant and can block lines.

Flocculation is most effective at a feed solids concentration determined by testwork, and many feedwells dilute the feed with overflow liquor to achieve it. The flocculant flow should be ratio-controlled to the solids feed rate so that the dose is maintained when throughput changes. Beyond a certain dose, additional flocculant does not increase settling rate and may produce a sticky bed that is difficult to rake and pump.

Bed control

Thickener control schemeFlocculant dose is set in proportion to the solids feed rate; underflow pump speed is adjusted to hold bed mass or bed level; underflow density is monitored and used to trim the bed setpoint.Feed flowand densityFlocculantpump: ratio to solidsBed pressureor bed levelUnderflowpump speedUnderflowdensityTrim bed setpointand floc dose
A common thickener control scheme. Rake torque, overflow clarity and underflow density are the alarms and checks that sit around it.

Bed level is measured with interface probes, sonar or floats, and bed mass is inferred from the bed pressure at the base of the tank. A common control scheme adjusts underflow pump speed to hold bed pressure or level, with underflow density monitored. If underflow density falls while the bed remains steady, the bed is not compacting, and flocculant, feed changes and residence time should be checked. If the bed continues to rise at full pump speed, solids are arriving faster than they can be removed and the feed must be reduced.

Rake torque is the main protection. Rising torque indicates a bed that is too deep or too dense, or one containing coarse material. Most drives lift the rakes or raise an alarm before reaching their limit, because a bogged rake causes a long and costly outage.

Troubleshooting

SymptomLikely causesFirst checks
Dirty overflowToo little flocculant, poor floc make-up, feed surge, bed too high, short-circuiting in the feedwellFlocculant flow and strength, feed rate, bed level
Low underflow densityBed too shallow, pump too fast, flocculant change, finer feedBed level or pressure, pump speed, feed size
Rising rake torqueBed too deep or dense, coarse or sanded material, scaleBed mass, underflow line blockage, feed coarseness
Underflow density swingsRat-holing (a channel through the bed), bed control tuningBed control loop, rake speed, underflow line
Flocculant use creeping upMake-up problems, feed solids changes, claysMake-up concentration and ageing, feedwell dilution

Glossary

Thickener
A large settling tank that separates slurry into clear overflow and dense underflow.
Flocculant
A polymer that binds fine particles into flocs that settle faster.
Feedwell
The central chamber where feed enters, mixes with flocculant and loses energy before settling.
Rise rate
Overflow flow divided by thickener area (m/h).
Solids loading
Dry solids feed rate divided by thickener area (t/h per m²).
Bed
The layer of settled, compacting solids in the lower part of the thickener.
Bed pressure
The pressure measured at the base, used to infer bed mass.
Rake torque
The turning load on the rake drive; a key protection measurement.

Frequently asked questions

How much flocculant should be added?

The dose that gives the required overflow clarity and underflow density, as determined by settling tests and plant trials. It should be expressed in g/t of dry solids, with the pump flow set in proportion to the solids feed.

Why is flocculant diluted before addition?

A dilute solution mixes through the feed more evenly, so that each floc receives the polymer it requires and less is wasted.

Should bed level or bed pressure be controlled?

Either can work. Bed pressure reflects bed mass, which relates more directly to underflow density; bed level is easier to interpret. Many plants measure both.

Why is the overflow dirty when the flocculant pump is running?

The make-up strength and ageing, the feed rate and solids, and the bed level should be checked. A bed close to the feedwell allows solids to escape to the overflow.

Discuss your plant with a metallurgist

Tiegel is a Perth metallurgy company. We help with testwork, plant optimisation, metal accounting and investigations, and we build the Tiegel Suite software.

Talk to a metallurgist

References and further reading

  1. Wills, B.A. and Finch, J.A. (2016). Wills' Mineral Processing Technology, 8th edition. Butterworth-Heinemann. Chapter 15, Dewatering.
  2. Concha, F. (2014). Solid-Liquid Separation in the Mining Industry. Springer.

Worked examples and charts marked illustrative use invented figures, not data from any operation.