Tiegel home Talk to a metallurgist

Solvent extraction stages calculator (McCabe-Thiele)

Describe the extraction isotherm with the fit y = ymax·x ÷ (K + x), fitted to your isotherm data. Enter feed, stripped organic, A/O and target raffinate to count theoretical stages.

Results

The example values are filled in so you can see how it works. Results update as you type.

The formula

D=[M]org[M]aqy=ys+AO(x−xR)

where

D
distribution coefficient at equilibrium
x, y
metal in aqueous and in organic (g/L)
ys
metal in the stripped organic entering extraction (g/L)
xR
metal in the raffinate leaving extraction (g/L)
AO
ratio of aqueous to organic flow

Want the background? Read Solvent extraction: isotherms, McCabe-Thiele diagrams and the number of stages.

Discuss your plant with a metallurgist

Tiegel is a Perth metallurgy company. We help with testwork, plant optimisation, metal accounting and investigations.

Talk to a metallurgist

These calculators use standard published formulas and are provided as a guide. Check results before relying on them for design or reporting.