Tiegel home Talk to a metallurgist

Slurry pipeline velocity and pump power calculator

Enter the slurry flow and pipe size to compare the pipe velocity with Durand's limit deposit velocity, then the head and efficiency for pump power.

Results

The example values are filled in so you can see how it works. Results update as you type.

The formula

VL=FL2gD(S−1)

where

VL
limit deposit velocity: below it, solids settle and form a bed in the pipe (m/s)
FL
Durand factor, read from charts for the particle size and solids concentration
g
gravitational acceleration, 9.81 m/s²
D
pipe inside diameter (m)
S
solids specific gravity

Want the background? Read Slurry pipelines: deposit velocity, pipe size and pump power with Durand's equation.

Discuss your plant with a metallurgist

Tiegel is a Perth metallurgy company. We help with testwork, plant optimisation, metal accounting and investigations.

Talk to a metallurgist

These calculators use standard published formulas and are provided as a guide. Check results before relying on them for design or reporting.