Tiegel home Talk to a metallurgist

Leach tanks in series calculator (CIL residue and recovery)

Enter the head grade, the unleachable gold, the leach rate constant from bottle rolls, the total residence time and the number of equal tanks. Add the throughput, solids density and tail solution grade for recovery and carbon movement.

Results

The example values are filled in so you can see how it works. Results update as you type.

The formula

unleached fraction, plug flow=e−kTunleached fraction,Ntanks=1(1+kτ)Nτ=TNr=r∞+(h−r∞)×unleached fraction

where

k
first-order leach rate constant for the leachable gold (h⁻¹), fitted to bottle roll or pilot data
T
total residence time of the circuit (h)
N, τ
number of equal tanks and residence time of each tank (h)
h
head grade (g/t)
r∞
gold that will not leach however long it stays, for example locked in sulphides (g/t)
r
predicted residue grade (g/t)

Want the background? Read CIL circuit modelling: leach kinetics in tanks in series, carbon loading and soluble gold loss.

Discuss your plant with a metallurgist

Tiegel is a Perth metallurgy company. We help with testwork, plant optimisation, metal accounting and investigations.

Talk to a metallurgist

These calculators use standard published formulas and are provided as a guide. Check results before relying on them for design or reporting.