Tiegel home Talk to a metallurgist

Thickener unit area and size calculator

Enter your settling test results. The calculator gives the underflow line height for the Talmage–Fitch construction, both unit areas, and the thickener area and diameter from the larger one.

Results

The example values are filled in so you can see how it works. Results update as you type.

The formula

Hu=C0H0CuUA=tuC0H0

where

C0, H0
initial solids concentration (t/m³) and initial pulp height (m) in the cylinder
Cu
target underflow solids concentration (t/m³)
Hu
height the pulp would have if all of it were at underflow concentration (m)
tu
time where the tangent at the compression point meets the line at height Hᵤ (days)

Want the background? Read Thickener sizing from settling tests: the Coe–Clevenger and Talmage–Fitch unit area methods.

Discuss your plant with a metallurgist

Tiegel is a Perth metallurgy company. We help with testwork, plant optimisation, metal accounting and investigations.

Talk to a metallurgist

These calculators use standard published formulas and are provided as a guide. Check results before relying on them for design or reporting.