Tiegel home Talk to a metallurgist

Reagent dosing calculations: g/t, solution strength and pump flow

Conversion of a reagent dose in g/t to a dosing pump flow, solution make-up by % w/v and % w/w, and flocculant dilution, with plant examples.

· 5 minute read · By

Reagent doses are specified in grams per tonne: 40 g/t of collector means 40 grams for every tonne of dry ore. Dosing pumps are set in litres per minute. The conversion is simple arithmetic, but an error by a factor of 10 or 1,000 is easily made, and an incorrect dose can cost recovery or reagent expenditure for weeks before it is detected.

The key quantity is the solution strength, the mass of reagent in each millilitre that the pump delivers. With the solution strength, the tonnage and the target dose, the pump setting follows directly. This article covers the calculations behind every reagent addition in a plant: conversion of doses to pump flows, solution make-up, flocculant dilution, and verification that the pump delivers the dose specified.

Reagent systemBags or bulk reagent mixed with water in a mixing tank, transferred to a storage tank, dosed by metering pumps to the plant addition points.Reagentbags or bulkMixing tankto set strengthStorage(day) tankMeteringpumpAddition pointconditioner or cellwater added herecalibrate the pump with a timed collection
A typical reagent system. The dose delivered depends on both the pump flow and the strength made up in the mixing tank.

Dose rate and pump flow

qpump(mL/min)=dose(g/t)×Q(t/h)60×s(g/mL)

where

qpump
dosing pump flow (mL/min)
dose
reagent addition per tonne of dry ore (g/t)
Q
dry ore feed rate (t/h)
s
reagent strength in grams of active reagent per millilitre of solution (10% w/v = 0.10 g/mL)

Worked example: a flotation plant treats 300 t/h of dry ore and requires 40 g/t of collector, made up as a 10% w/v solution (100 g per litre, or 0.10 g/mL). The reagent requirement is 40 × 300 = 12,000 g/h, or 200 g/min, and the pump flow is 200 ÷ 0.10 = 2,000 mL/min, or 2.0 L/min.

Pump flow for each doseAt 300 t/h and 10% strength, every 10 g/t needs 0.5 L/min of solution: 1.0 L/min at 20 g/t and 3.0 L/min at 60 g/t.012320 g/t: 1.0 L/min1.0 L/min20 g/t30 g/t: 1.5 L/min1.5 L/min30 g/t40 g/t: 2.0 L/min2.0 L/min40 g/t50 g/t: 2.5 L/min2.5 L/min50 g/t60 g/t: 3.0 L/min3.0 L/min60 g/tSolution flow (L/min)
Dosing pump flow for a 10% w/v collector solution at 300 t/h of dry ore.

Daily consumption is 40 g/t × 7,200 t/d = 288 kg/d of collector, so a 1,000 kg bag lasts about three and a half days. A weekly comparison of bags used against this figure detects pump errors and leaks.

Grams per tonne is equivalent to parts per million by mass. Leaching reagent doses are often expressed in kilograms per tonne instead: 0.4 kg/t of cyanide at 350 t/h is 140 kg/h.

Solution strength: % w/v and % w/w

Two definitions are in common use, and confusion between them is a frequent source of error. Percent w/v (weight per volume) is grams of reagent per 100 mL of solution, so 10% w/v is 100 g/L. Percent w/w (weight per weight) is grams of reagent per 100 g of solution, and is converted to g/L by multiplying by the solution density:

s(g/L)=10×% w/w×ρsoln(kg/L)Vfinal=mass of reagents

where

% w/w
strength by mass: grams of reagent per 100 g of solution
ρsoln
density of the solution (kg/L)
Vfinal
final volume of solution made from a given mass of reagent (L, with s in g/L)

A 10% w/w solution with a density of 1.05 kg/L contains 10 × 10 × 1.05 = 105 g/L. If the pump calculation had assumed 100 g/L, the dose would be 5% high. For the 40 g/t example, the correct pump flow at 105 g/L is 200 ÷ 0.105 = 1.90 L/min.

Product purity must also be taken into account: if the product is 90% active, the active strength of a solution made from it is 90% of the nominal strength.

Batch make-up

To make a 10% w/v solution from a 1,000 kg bag, the final volume must be 1,000,000 g ÷ 100 g/L = 10,000 L. The bag is added to part of the water and mixed until dissolved, and the tank is then topped up to the 10,000 L mark. Adding the bag to 10,000 L of water gives a slightly weaker solution, because the dissolved solid adds volume. For a % w/w solution both components are weighed: 1,000 kg of reagent in 9,000 kg of water gives 10% w/w.

Flocculant stock and dilution

Flocculant is prepared as a stock solution and diluted further before addition, because dilute flocculant mixes into slurry far more effectively.

Worked example: a thickener receives 2,400 t/d (100 t/h) of dry solids and requires 25 g/t of flocculant, with a stock strength of 0.25% w/v (2.5 g/L) and a dosing strength of 0.025% (0.25 g/L). The flocculant requirement is 25 × 100 = 2,500 g/h, so the stock flow is 2,500 ÷ 2.5 = 1,000 L/h (16.7 L/min). The dilute flow at 0.25 g/L is 2,500 ÷ 0.25 = 10,000 L/h, so 9,000 L/h of dilution water is added to the stock line.

The thickener sizing article describes how settling tests establish the dose.

Verification of pump delivery

  1. Timed collection: divert the pump discharge into a measuring cylinder or bucket for a timed period, for example 60 seconds; 1.98 L in 60 s is 1.98 L/min. Repeat at the normal setting after any pump maintenance.
  2. Calibration column: many dosing systems have a graduated column on the pump suction, and the fall in level is timed with the tank valve closed.
  3. Daily reconciliation: compare reagent consumption (from tank levels or bags) with the dose multiplied by tonnage. A persistent discrepancy indicates a pump, flowmeter or tonnage error.
  4. Strength checks: titrate or measure the density of the made-up solution periodically, because a mixing error affects every subsequent dose.

Glossary

g/t
Grams of reagent per tonne of dry ore; the same as parts per million by mass.
% w/v
Grams of reagent per 100 mL of solution.
% w/w
Grams of reagent per 100 g of solution.
Stock solution
A concentrated solution made in the mixing tank and stored for dosing.
Dosing pump
A metering pump that delivers a set flow of reagent solution.
Flocculant
A polymer that binds fine particles into larger flocs that settle faster.
Active content
The fraction of a reagent product that is the active chemical.
Calibration column
A graduated tube on a pump's suction used to measure its actual flow.

Frequently asked questions

How is g/t converted to mL/min?

Multiply the dose in g/t by the dry feed rate in t/h, divide by 60 to obtain grams per minute, then divide by the solution strength in g/mL.

What is the difference between % w/v and % w/w?

% w/v is grams per 100 mL of solution; % w/w is grams per 100 g of solution. Multiplying % w/w by ten and by the solution density in kg/L gives g/L.

Why is flocculant diluted before addition?

Dilute flocculant disperses through the slurry more evenly and quickly, so less is needed for the same settling performance.

Is g/t the same as ppm?

Yes, by mass: one gram per tonne is one part per million.

Discuss your plant with a metallurgist

Tiegel is a Perth metallurgy company. We help with testwork, plant optimisation, metal accounting and investigations, and we build the Tiegel Suite software.

Talk to a metallurgist

References and further reading

  1. Wills, B.A. and Finch, J.A. (2016). Wills' Mineral Processing Technology, 8th edition. Butterworth-Heinemann. Chapter 12, Froth flotation.
  2. Bulatovic, S.M. (2007). Handbook of Flotation Reagents: Chemistry, Theory and Practice, Volume 1. Elsevier.

Worked examples and charts marked illustrative use invented figures, not data from any operation.